Split type High Power Series WSYG140DG6 / WOYG140LCTA

Hydraulic unit and Outdoor unit

Hydraulic Unit :
WSYG140DG6
Outdoor Unit :
WOYG140LCTA
Download :
Catalogue

Features

  • High leaving water temperature
  • High COP
  • 2 Zone individual control
  • Automatic heating curve control
  • High durability
  • Emergency operation

Specification

Capacity range 14
7°C/35°C floor heating *1 Heating capacity 13.50 kW
Input Power 3.23 kW
COP 4.18
2°C/35°C floor heating *1 Heating capacity 12.00 kW
Input Power 3.87 kW
COP 3.1
-7°C/35°C floor heating *1 Heating capacity 11.54 kW
Input Power 5.08 kW
COP 2.27
Scroll

Space heating characteristics *2

Temperature application 55 °C 35 °C
Energy Efficiency Class A+ A+
Rated heat output 11 kW 13 kW
Seasonal space heating energy efficiency (ηs) 113 % 148 %
Annual energy consumption 8041 kWh 6824 kWh
Sound Power Level Hydraulic indoor unit 46 dB(A)
Outdoor unit 69 dB(A)
Scroll

Hydraulic indoor unit Specification

Power source Phase 1 ø
Voltage 230 V
Frequency 50 Hz
Net Dimensions Height 800 mm
Width 450 mm
Depth 457 mm
Net Weight 42 kg
Water circulation Min/Max 24.4 / 48.7 L/min
Buffer tank capacity 16 L
Expansion vessel capacity 8 L
Leaving water temperature range Max 60 °C
Water pipe connection diameter Flow Ø 25.4 mm
Return Ø 25.4 mm
Backup heater Capacity 6.0 (3.0kW×2pcs.) kW
Scroll

Outdoor unit specification

Power source Phase 1 ø
Voltage 230 V
Frequency 50 Hz
Current Max 25.0 A
Net Dimensions Height 1,290 mm
Width 900 mm
Depth 330 mm
Net Weight 92 kg
Refrigerant (Global Warming Potential) R410A (2,088)
Refrigerant amount 2.50 kg
Additional refrigerant charge amount 50 g/m
Connection Pipe Diameter Liquid Ø 9.52 mm
Gas Ø 15.88 mm
Pipe Length Min/Max 5 / 20 m
Pre Charge 15 m
Height Difference Max 15 m
Operation Range Heating -25 to 35 °C
Scroll
*1 :
The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.
*2 :
All information of ErP can be available for downloaded from www.fujitsu-general.com/global/products/erp-ecodesign/index.html.

Dimensions

Hydraulic Unit : WSYG140DG6

Hydraulic indoor unit

Outdoor Unit : WOYG140LCTA

Outdoor unit

Optional Parts

2nd Circuit Kit
UTW-KZSXE
Boiler Connection kit
UTW-KBSXD
Balancing vessel
UTW-TEVXA
DHW kit
UTW-KDWXD (External)
DHW tank
UTW-T20XA (200 Liter)
DHW tank
UTW-T30XA (300 Liter)
DHW tank
UTW-T30XD (300 Liter)
Circulating pump
UTW-PHFXD
Swimming Pool kit
UTW-KSPXD
Heat Exchanger for swimming pool kit
UTW-ESPXA
Cooling kit
UTW-KCLXD
Regulation Extension Kit
UTW-KREXD
Low Noize Kit
UTW-KLNXE
Cascade Master Kit (incl. LPB Clip)
UTW-KCMXE
Cascade Slave Kit (incl. LPB Clip)
UTW-KCSXE
HMI Kit
UTW-KHMXE
Remote Controller
UTW-C74TXF
Remote Controller
UTW-C74HXF
Remote Controller
UTW-C78XD
Remote Controller
UTW-C78XD-E
Room Themostat
UTW-C55XA
Room Themostat
UTW-C58XD
Outdoor Sensor Transmitter
UTW-MOSXD
RF Modules
UTW-MRCXD
Web server
UTW-KW1XD
Web server
UTW-KW4XD
LPB Clip
UTW-KL1XD
Modbus Clip
UTW-KMBXE
Base Heater
UTW-HAMXE
Base Heater
UTW-HAMXF
Service Tool (incl. OCI700 adaptor)
UTW-KSTXD
Service Tool Software
UTW-KPSXD
External connect kit
UTY-XWZXZ2
UTW-KHMXE,UTW-C74TXF,UTW-C74HXF :
19 Languages included,no separate Estern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
UTW-C78XD-E :
Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
UTW-KSTXD :
UTW-KL1XD is required for the connection.
UTW-KPSXD :
UTW-KW1XD or UTW-KW4XD is required for the connection.
UTW-KMBXE :
Additional optional part necessary